Technical proposal of high and low temperature test chamber WSD-8101


First, performance indicators:


1. Product name: high and low temperature alternating humidity and heat test chamber


2. Sample restrictions:


This test equipment is prohibited:


Test and storage of samples of flammable, explosive and volatile substances


Testing and storage of corrosive substance samples


Testing or storage of biological samples


Test and storage of samples from strong electromagnetic emission sources


3. Volume and size:


3.1 Nominal content product (L) : 225L


3.2 Nominal inner box size (mm) : D600×W800XH850


3.3 Water: The back of the box will automatically add water (the water pressure is controlled at about 3 kg) or open the water tank manually


4. Performance:


4.1 Test Environment Conditions:


The airflow around the equipment is smooth, no high concentration dust, no corrosive or flammable and explosive gas


Ambient temperature: 5 ~ 28℃


Relative humidity ≤85%RH


4.2 Test Method:


4.2.1 Temperature limit range: -40℃ ~ +150℃


The recommended long-term operating temperature range is -30 ° C to 120 ° C


4.2.2 Temperature fluctuation: ±0.5℃


4.2.3 Temperature deviation: ±2.0℃


4.2.4 Temperature change rate:


4.2.4.1 Heating rate: 3℃~4℃/ min (non-linear no-load)


4.2.4.2 Cooling Rate: 0.7℃~1℃/ min (nonlinear no-load)


4.2.5 Humidity range: 30% ~ 98%RH (+20℃~+85℃) (refer to the controllable temperature and humidity range shown in the figure below)























4.2.6 Relative humidity deviation:


±3.0%RH (humidity > 75%RH)


±5.0%RH (humidity ≤ 75%RH)


The above indicators are tested without sample load in the box (except for special instructions).


4.2.7 Meet the test standards:


GB/T2423.1-2001 Test A: Low temperature test method


GB/T2423.2-2001 Test B: High temperature test method


GB/T2423.3-1993 Test Ca: Constant damp heat test


GJB150.3-1986 High temperature test


GJB150.4-1986 Low temperature test


Second, function introduction:


1. Structural features:


1.1 Insulation enclosure structure:


Outer wall: high-grade steel spray


Inner wall: SUS304 stainless steel plate


Insulation material: ultrafine glass fiber


1.2 Air conditioning channels:


Fan, heater, evaporator (and dehumidifier), drainage device, humidifier, dry burning preventer, wet bulb temperature, sensor, wet bulb sink


1.3 Standard configuration of laboratory body:


1.3.1 Single door opening


1.3.2 The door is equipped with an electrically heated anti-condensation hollow glass observation window


1.4 Control Panel (on the distribution control cabinet) :


Temperature (humidity) control display, operation button, overtemperature protection setting device, lighting switch


1.5 Machinery Room:


The mechanical room includes: refrigeration unit, drainage device, fan, distribution control cabinet, humidification and humidity measuring water control device


1.6 Distribution control cabinet:


Heat dissipation fan, buzzer, power distribution board, temperature and humidity recorder (optional), RS-232 physical interface (to be purchased with centralized monitoring software)


1.7 Heater:


1.7.1 Heater material: stainless steel fin seamless heating tube


1.8 Humidifier:


1.8.1 Humidification Method: Use an external humidifier


1.8.2 Humidifier quality: stainless steel


1.8.3 Humidifier control mode: contactless periodic pulse width adjustment, SSR (solid state relay)


1.8.4 Humidifier device: water level control device, heater anti-dry burning device


2. Refrigeration system:


2.1 Working mode: air-cooled mechanical compression single-stage refrigeration


2.2 Refrigeration compressor: piston compressor


2.3 Evaporator: finned heat exchanger (double as dehumidifier)


2.4 Evaporative condenser: brazed plate heat exchanger


2.5 Control mode of refrigerator:


2.5.1 The touch screen (programmable logic controller) automatically adjusts the operating conditions of the refrigerator according to the test conditions


2.6 Refrigerant: R404A/R23 (ozone loss index is 0)


2.7 Others:


2.7.1 The main components are made of international high-quality brand products


2.7.2 Compressor cooling fan


3. Electrical control system:


3.1 Temperature and Humidity controller (model) : Taiwan "Velen" TH4310


3.2 Display: 4.3-inch true color LCD display


3.3 Operation mode: program mode, fixed value mode


3.4 Setting Mode: Chinese menu, touch screen input


3.5 Program Capacity: Editable: 20 programs. Each program has a maximum of 50 steps and can have 20 loops


(Maximum 99 cycles per cycle step)


Fixed: 10 programs, programs can be linked


3.6 Setting Range: Temperature: Adjust according to the temperature working range of the equipment (upper limit +5℃, lower limit -5℃)


Humidity: (0 ~ 100) % RH(Temperature and humidity test equipment)


3.7 Resolution: Temperature: 0.1℃; Time: 0.1min;


Humidity: 0.1% RH(temperature and humidity test equipment)


3.8 Input: Thermocouple


3.9 Communication Function (Optional) : RS-485 interface,


3.10 Auxiliary functions: fault alarm and cause, processing prompt function, power off protection function, upper and lower limit temperature protection function, timing function (automatic stop operation).


3.11 Temperature and humidity measurement: Temperature: PT100 thermocouple; Humidity: Wet and dry bulb thermometer method (wet and hot type)


4. Supply water to the hot and humid system


4.1 External water supply: distilled water, pure water, deionized water (resistivity greater than 500Ω·m) (user provided)


4.2 Internal Water Supply: Lift the water pump


4.3 Location of the water supply device: Connect the pipe at the back of the box or manually add water directly


4.4 Water storage tank volume: 10L


5. Safety protection device


5.1 Refrigeration system:


5.1.1 Compressor Overpressure


5.1.2 Compressor motor Overheats


5.1.3 Compressor motor overcurrent


5.2 Humidification system:


5.2.1 Dry burning of heating tube


5.2.2 Abnormal Water Supply


5.2.3 Abnormal Drainage


5.3 Laboratory:


5.3.1 Adjustable overtemperature protection


5.3.2 The limit Overtemperature of the air conditioning channel


5.3.3 Fan motor overheating


5.4 Others:


5.4.1 Total power supply phase sequence and phase loss protection


5.4.2 Leakage protection


5.4.3 Load Short-circuit Protection


6. Other configuration:


Power cable: 5-core (4-core cable + protective ground cable) 1 cable (2.5m long)


7. Purchase accessories (functions) : when necessary, the contract or technical agreement is specifically stated


7.1 Lead hole: The lead hole has a diameter of φ50mm, the number of 1, its position can be allowed in the box structure and does not affect the performance of the condition can be customized according to user requirements.


8. Conditions of Use (The User guarantees the following conditions) :


8.1 Venue:


8.1.1 Ground level, good ventilation, free of flammable, explosive, corrosive gases and dust


8.1.2 There is no source of strong electromagnetic radiation nearby


8.1.3 There is a floor drain near the equipment (within 2 meters from the refrigeration unit)


8.1.4 Ground bearing capacity: not less than 500kg/m2


8.1.5 Reserve proper maintenance space around devices


8.2 Environmental Conditions:


8.2.1 Temperature: 5℃ ~ 28℃


8.2.2 Relative humidity: ≤ 85%RH


8.2.3 Air pressure: 86 ~ 106kpa


8.3 Power Supply: AC380V three-phase four-wire + PGND cable


8.3.1 Allowable voltage fluctuation range: AC (1±10%) 380V


8.3.2 Allowed frequency fluctuation range: (1±1%) 50Hz


8.3.3 The grounding resistance of the PGND cable is less than 4 OhMs. Power supply in TN-S mode or TT mode


8.3.4 The user is required to configure the air or power switch of the corresponding capacity for the device at the installation site, and the switch must be independent and dedicated for the device


8.3.5 Power Capacity: 4.5KVA


8.4 Requirements for the Storage Environment:


8.4.1 When the device is not working, the ambient temperature should be kept within +0 ° C to 35 ° C










High and low temperature alternating wet heat test chamber main parts detail


NO.


Part name


Gauge lattice


brand



1


Temperature and humidity controller


TH4310


Taiwan screen



2


compressor


Model 2480 or 2511


Taican



3


refrigerant


R404a Environmental refrigerant


Honeywell USA



4


capillaries


Inside diameter 1.0


Kawamura



5


Solenoid valve


1028/3


Italian CASTEL



6


Filter dryer


EK-083S


Emerson



7


condenser


custom


Taiwan Zhongli



8


evaporator


custom


Taiwan Zhongli



9


humidifier


1.5KW stainless steel


Nantong Baiyun



10


Humidifier anti-dry burn switch


TS-120SF-C


South Korean RAINBOW



11


Solid-state relay


SSR-40DA


Goodall



12


Air switch


C65


Chint



13


relay


MY2N1 AC220V


Japanese Omron



14


Ac contactor


LC1-E Series


Chint



15


Thermal relay


LRE Series


Chint



16


Platinum sensor


PT100 ¢5 SUS304


Shanghai Shengmin



17


Antifreeze observation window


Transparent electrothermal film hollow tempered glass


Humen Teli



18